Prisms and Optical Principles
Teaching images
91. Physics of a Prism
- Clinical Analogy: Think of a prism as a 'deflection machine'.
- Just as a river bends around a rock, light bends toward the base of the prism while the image seen by the eye appears displaced toward the apex.
- This single principle underlies clinical applications including strabismus measurement and the prismatic effects of bifocal lenses.
Structure and Geometry
Teaching image
1A prism is a transparent medium bounded by two non-parallel plane surfaces (the refracting surfaces) meeting at an angle called the apical angle (A). The third surface is the base.
| Component | Definition | Clinical Relevance |
|---|---|---|
| Apex | Thinnest edge; tip of the prism | Image displacement occurs toward apex |
| Base | Thickest edge; opposite the apex | Light bends toward base |
| Apical angle (A) | Angle between the two refracting faces | Determines power of the prism |
| Angle of deviation (D) | Angle between incident and emergent ray | Related to prism diopter (PD) by: • Prism diopter (PD) = 100 × tan(angle of deviation (D)) |
| Minimum deviation | Position where deviation is least; • The refracted ray inside the prism is parallel to the base | Used in spectrometry; • Not the usual dispensing position for ophthalmic glass spectacle prisms • Minimum-deviation positioning may be used with plastic prisms and is difficult to obtain clinically |
| Component | Definition | Clinical Relevance |
|---|---|---|
| Apex | Thinnest edge; tip of the prism | Image displacement occurs toward apex |
| Base | Thickest edge; opposite the apex | Light bends toward base |
| Apical angle (A) | Angle between the two refracting faces | Determines power of the prism |
| Angle of deviation (D) | Angle between incident and emergent ray | Related to prism diopter (PD) by: • Prism diopter (PD) = 100 × tan(angle of deviation (D)) |
| Minimum deviation | Position where deviation is least; • The refracted ray inside the prism is parallel to the base | Used in spectrometry; • Not the usual dispensing position for ophthalmic glass spectacle prisms • Minimum-deviation positioning may be used with plastic prisms and is difficult to obtain clinically |
Snell's Law and Prism Deviation
- For a prism of refractive index n and apical angle A, the deviation D depends on the angle of incidence. At minimum deviation:
- Dmin = 2i – A | n = sin[(A + Dmin)/2] / sin(A/2)
- For small apical angles (thin prisms used clinically): D ≈ (n – 1) × A
- For thin prisms, the net deviation is the vector sum of the individual prism deviations.
Prism Dioptre - Definition and Units
Teaching image
1- A prism dioptre (∆ or PD) is defined as a deviation of 1 centimetre at 1 metre distance.
- It is the universal clinical unit of prismatic power.
- 1 prism dioptre (PD) = 1 centimetre displacement of an image at 1 metre.
- Conversion: tan(θ°) = prism dioptres/100.
- 1° ≈ 1.75 prism dioptres (PD).
- For small angles: 1° ≈ 2 prism dioptres (∆) is the common approximation.
- 10 prism dioptres (∆) ≈ 5.7°.
- 20 prism dioptres (∆) ≈ 11.3°.
- 45 prism dioptres (∆) ≈ 24.2°.
- TRAP: The relationship 1° = 2 prism dioptres (∆) is only an approximation.
- For an accurate conversion at any deviation, use the tangent formula.
- The Krimsky test uses prisms to measure the deviation directly in prism dioptres (PD).
Prentice's Rule - The Most Tested Formula
Teaching image
1Prentice's Rule quantifies the prismatic effect at any point on a lens away from the optical centre: • P (prism dioptres) = c (centimetres) × F (dioptres) Where: • P = prismatic power induced • c = distance from optical centre in centimetres • F = lens power in dioptres (use absolute value; sign determines direction) Direction rule: • Convex (+) lens → base DOWN above centre, base UP below centre • Concave (–) lens → base UP above centre, base DOWN below centre
Worked Example: • A +4.00 D lens with optical centre 3 millimetres above the visual axis: • P = 0.3 centimetres × 4 D = 1.2∆ base UP (because looking through the lens below its optical centre produces a base-up effect)
| Lens Type | Looking Up (above optical centre) | Looking Down (below optical centre) | Looking In (nasal) | Looking Out (temporal) |
|---|---|---|---|---|
| +Convex | Base DOWN | Base UP | Base OUT | Base IN |
| –Concave | Base UP | Base DOWN | Base IN | Base OUT |
| Lens Type | Looking Up (above optical centre) | Looking Down (below optical centre) | Looking In (nasal) | Looking Out (temporal) |
|---|---|---|---|---|
| +Convex | Base DOWN | Base UP | Base OUT | Base IN |
| –Concave | Base UP | Base DOWN | Base IN | Base OUT |
- TRAP: In anisometropia, differential prismatic effect at near (looking down through reading area) creates vertical imbalance.
- This is the basis for slab-off prism prescription - always prescribed in the MORE MINUS (or less plus) eye.
2. Types of Prisms and Their Clinical Uses
Teaching image
1Standard Ophthalmic Prisms
Teaching image
1| Prism Type | Construction | Key Use | Advantage/Limitation |
|---|---|---|---|
| Loose prism bar | • Calibrated prism bar • Base-in (BI) • Base-out (BO) • Base-up (BU) • Base-down (BD) | • Cover test • Prism and alternate cover test (PACT) | • Prisms of different orientations can be combined for horizontal and vertical deviations |
| Fresnel press-on prism | • Polyvinyl chloride (PVC) membrane with microprisms • Press onto spectacle lens | • Large deviations • Postoperative use • Temporary use • Diplopia treatment | • May reduce visual acuity (VA) • May cause chromatic aberrations, particularly at higher powers • May be unsuitable for tasks requiring fine visual resolution |
| Ground-in prism | • Incorporated into spectacle lens during grinding | • Long-term correction of small deviations | • Can exceed 8 prism dioptres per lens • Higher powers make lenses thicker, heavier, and more expensive |
| Risley rotary prism | • Two prisms counter-rotated • Power varies 0–30 prism dioptres | • Binocular vision assessment • Smooth vergence testing | |
| Maddox rod with prism bar | • Used with Maddox rod | • Dissociation • Subjective deviation measurement | • Subjective • Requires patient cooperation |
| Base-out prism test | • 4 prism dioptres base-out (BO) placed before one eye | • Microtropia/monofixation detection | • Classic diagnostic use |
| Prism Type | Construction | Key Use | Advantage/Limitation |
|---|---|---|---|
| Loose prism bar | • Calibrated prism bar • Base-in (BI) • Base-out (BO) • Base-up (BU) • Base-down (BD) | • Cover test • Prism and alternate cover test (PACT) | • Prisms of different orientations can be combined for horizontal and vertical deviations |
| Fresnel press-on prism | • Polyvinyl chloride (PVC) membrane with microprisms • Press onto spectacle lens | • Large deviations • Postoperative use • Temporary use • Diplopia treatment | • May reduce visual acuity (VA) • May cause chromatic aberrations, particularly at higher powers • May be unsuitable for tasks requiring fine visual resolution |
| Ground-in prism | • Incorporated into spectacle lens during grinding | • Long-term correction of small deviations | • Can exceed 8 prism dioptres per lens • Higher powers make lenses thicker, heavier, and more expensive |
| Risley rotary prism | • Two prisms counter-rotated • Power varies 0–30 prism dioptres | • Binocular vision assessment • Smooth vergence testing | |
| Maddox rod with prism bar | • Used with Maddox rod | • Dissociation • Subjective deviation measurement | • Subjective • Requires patient cooperation |
| Base-out prism test | • 4 prism dioptres base-out (BO) placed before one eye | • Microtropia/monofixation detection | • Classic diagnostic use |
Fresnel Prisms - Expanded
Fresnel (press-on) prisms are made of flexible optical-grade polyvinyl chloride (PVC) with a series of angular grooves on one side. The smooth side is applied to the lens surface with water.
- Available powers: 1–40 prism dioptres (∆) (standard kit)
- Visual acuity (VA) and contrast sensitivity decrease as Fresnel prism power increases; higher powers may be less well tolerated.
- Chromatic aberration - polyvinyl chloride (PVC) Fresnel prisms increase chromatic dispersion.
- Reduced contrast sensitivity - contrast sensitivity decreases as Fresnel prism power increases.
- Indicated when: Fourth nerve palsy with small vertical deviation; thyroid-related orbitopathy with diplopia; neurological diplopia awaiting recovery; preoperative assessment; postoperative diplopia.
- Fresnel prisms may reduce visual acuity, particularly at higher prism powers. Warn patients that they may cause blur and reduced visual acuity. Clean prism grooves of dust or debris; refit or replace the prism if it peels, curls, or no longer lies flat.
Reflecting Prisms
Teaching image
1| Prism | Type of Reflection | Application |
|---|---|---|
| Porro prism | • Two total internal reflection (TIR) reflections • Image inverted (single Porro prism) | • Binoculars • Telescopes |
| Dove prism | • Single total internal reflection (TIR) • Inverts image | • Rotating image systems |
| Roof (Abbe) prism | • Roof edge • Compact image erection | • Compact binoculars |
| Pechan prism | • Multiple internal reflections • Image erect | • Endoscopes • Periscopes |
| Amici prism | • Roof + total internal reflection (TIR) • Rotates image 180° about the optical axis | • Slit-lamp design |
| Prism | Type of Reflection | Application |
|---|---|---|
| Porro prism | • Two total internal reflection (TIR) reflections • Image inverted (single Porro prism) | • Binoculars • Telescopes |
| Dove prism | • Single total internal reflection (TIR) • Inverts image | • Rotating image systems |
| Roof (Abbe) prism | • Roof edge • Compact image erection | • Compact binoculars |
| Pechan prism | • Multiple internal reflections • Image erect | • Endoscopes • Periscopes |
| Amici prism | • Roof + total internal reflection (TIR) • Rotates image 180° about the optical axis | • Slit-lamp design |
- Total Internal Reflection (TIR) occurs when light hits the interface at an angle > critical angle (C), with light travelling from higher to lower refractive index.
- For a glass–air interface, sin C = 1/n; generally, sin C = n₂/n₁ (n₁ > n₂).
- For glass (n=1.5), C ≈ 41.8°.
- Prism binoculars use total internal reflection to fold the optical path, shortening instrument length.
Free preview ends here
Keep reading Prisms and Optical Principles
10 more sections are included with the Clinical plan.
- Prisms in Strabismus - Clinical Framework
- Prism and Alternate Cover Test (PACT)
- Therapeutic Uses of Prisms in Specific Conditions
- Prisms in Spectacle Design
- Prisms in Ophthalmic Instruments
- Dispersion, Chromatic Aberration and Abbe Number