Free previewYou're reading the free part of this topic. The rest is included with Clinical.See what's included
Implantable Collamer Lens (ICL)
Cataract & Refractive Surgery
Teaching images
81. Clinical Analogy & Conceptual Overview
Teaching image
1Exam pearl
- Clinical Analogy: The Contact Lens Inside the Eye Imagine a contact lens that is placed inside the eye, floating harmlessly in the posterior chamber - the space between the iris and the crystalline lens - without touching either structure.
- Unlike LASIK, which sculpts the cornea (permanently altering its architecture), the ICL works by adding a new optical element to the existing optical system.
- Think of it as adding a corrective lens inside a camera without modifying the existing lens.
- The beauty: it is reversible, additive, and does not consume corneal tissue.
- If the natural lens needs removal later (e.g., for cataract), the ICL comes out first - leaving the eye in essentially its pre-surgery anatomical state.
- What is an ICL?
- The Implantable Collamer Lens (ICL) is a phakic posterior chamber intraocular lens made from Collamer - a proprietary biocompatible copolymer of porcine collagen and hydroxyethyl methacrylate (HEMA).
- It is placed in the posterior chamber between the posterior iris surface and the anterior crystalline lens capsule, supported in the ciliary sulcus.
| Parameter | Detail |
|---|---|
| Manufacturer | • STAAR Surgical (Monrovia, CA, USA) |
| Material | • Collamer (a proprietary HEMA/porcine-collagen-based biocompatible polymer) |
| Location | • Posterior chamber phakic IOL (PC-pIOL) |
| Current Model | • EVO+ ICL (V5). • KS-AquaPORT is documented for the earlier V4c design. |
| Available Powers | • Myopia: −3.0 to −16.0 D spherical lens powers • FDA-labeled myopia correction/reduction: −3.0 to −20.0 D • Hyperopia: current FDA EVO/EVO+ hyperopic range not established; use only with model- and region-specific labeling. • Toric: up to 6.0 D cylinder under applicable regional labeling • US-labeled toric indication: 1.0–4.0 D cylinder |
| Reversibility | • Reversible; lens removal, replacement, or repositioning may be performed when clinically indicated. |
| FDA Approval (EVO+) | • 2022 (USA) • Earlier approval, marketing, and implantation in Europe and Asia |
| Parameter | Detail |
|---|---|
| Manufacturer | • STAAR Surgical (Monrovia, CA, USA) |
| Material | • Collamer (a proprietary HEMA/porcine-collagen-based biocompatible polymer) |
| Location | • Posterior chamber phakic IOL (PC-pIOL) |
| Current Model | • EVO+ ICL (V5). • KS-AquaPORT is documented for the earlier V4c design. |
| Available Powers | • Myopia: −3.0 to −16.0 D spherical lens powers • FDA-labeled myopia correction/reduction: −3.0 to −20.0 D • Hyperopia: current FDA EVO/EVO+ hyperopic range not established; use only with model- and region-specific labeling. • Toric: up to 6.0 D cylinder under applicable regional labeling • US-labeled toric indication: 1.0–4.0 D cylinder |
| Reversibility | • Reversible; lens removal, replacement, or repositioning may be performed when clinically indicated. |
| FDA Approval (EVO+) | • 2022 (USA) • Earlier approval, marketing, and implantation in Europe and Asia |
2. Biomaterial & Design Specifications
Teaching image
1A. Collamer Material
- Collamer is a proprietary collagen copolymer unique to STAAR Surgical.
- Collagen: ~0.2% porcine collagen - provides biocompatibility and surface properties
- HEMA (Hydroxyethyl methacrylate): a hydrophilic monomer contributing to the material’s flexibility and optical properties.
- UV-absorbing chromophore: attenuates ultraviolet transmission through the lens; clinical reduction of retinal disorders has not been established.
- Water content: reported values vary by source and lens specification, approximately 34–40%; Collamer is hydrophilic.
| Property | Collamer | Silicone | Acrylic |
|---|---|---|---|
| Biocompatibility | • Biocompatible (HEMA/porcine-collagen-based polymer) | • Good | • Good |
| Water content | • ~34% | • Very low | • Depends on subtype - hydrophobic acrylic usually <1%; hydrophilic acrylic approximately 18–38% |
| UV protection | • Yes (built-in chromophore) | • UV protection depends on incorporation of a UV-absorbing chromophore; the chromophore may be added or chemically bonded during manufacture. | • UV protection is product/design dependent • UV-absorbing chromophores may be incorporated. |
| Foldability | • Yes (roll-up) | • Yes | • Yes (heat-sensitive) |
| Fibronectin adhesion | • High (promotes biocompatibility) | • Lower fibronectin adhesion than hydrophobic soft acrylate | • Greater fibronectin adhesion than silicone and PMMA in comparative studies |
| Glistening | • No | • Generally fewer glistenings than hydrophobic acrylic, but glistenings can occur | • May exhibit glistening; susceptibility varies by formulation, with hydrophobic acrylic often showing more glistenings than hydrophilic acrylic. |
| Property | Collamer | Silicone | Acrylic |
|---|---|---|---|
| Biocompatibility | • Biocompatible (HEMA/porcine-collagen-based polymer) | • Good | • Good |
| Water content | • ~34% | • Very low | • Depends on subtype - hydrophobic acrylic usually <1%; hydrophilic acrylic approximately 18–38% |
| UV protection | • Yes (built-in chromophore) | • UV protection depends on incorporation of a UV-absorbing chromophore; the chromophore may be added or chemically bonded during manufacture. | • UV protection is product/design dependent • UV-absorbing chromophores may be incorporated. |
| Foldability | • Yes (roll-up) | • Yes | • Yes (heat-sensitive) |
| Fibronectin adhesion | • High (promotes biocompatibility) | • Lower fibronectin adhesion than hydrophobic soft acrylate | • Greater fibronectin adhesion than silicone and PMMA in comparative studies |
| Glistening | • No | • Generally fewer glistenings than hydrophobic acrylic, but glistenings can occur | • May exhibit glistening; susceptibility varies by formulation, with hydrophobic acrylic often showing more glistenings than hydrophilic acrylic. |
B. Lens Design & Dimensions
| Feature | V4 (Older) | V4c / EVO ICL | EVO+ Visian ICL |
|---|---|---|---|
| Central port (AquaPORT) | • Absent | • 360 μm | • 360 μm |
| Optic diameter | • 4.5–6.0 mm | • 4.9–5.8 mm | • 5.0–6.1 mm |
| Overall diameter | • 11.5, 12.0, 12.5, and 13.0 mm | • 12.1, 12.6, 13.2, and 13.7 mm | • 12.1, 12.6, 13.2, and 13.7 mm |
| Haptic design | • Plate haptic (feet) | • Plate haptic (feet) | • Plate haptic (feet) |
| PI required | • Yes | • No | • No |
| Central thickness | • Varies with dioptric power | • Varies with dioptric power | • Varies with dioptric power |
| Profile | • Convex-concave | • Convex-concave | • Convex-concave |
| Feature | V4 (Older) | V4c / EVO ICL | EVO+ Visian ICL |
|---|---|---|---|
| Central port (AquaPORT) | • Absent | • 360 μm | • 360 μm |
| Optic diameter | • 4.5–6.0 mm | • 4.9–5.8 mm | • 5.0–6.1 mm |
| Overall diameter | • 11.5, 12.0, 12.5, and 13.0 mm | • 12.1, 12.6, 13.2, and 13.7 mm | • 12.1, 12.6, 13.2, and 13.7 mm |
| Haptic design | • Plate haptic (feet) | • Plate haptic (feet) | • Plate haptic (feet) |
| PI required | • Yes | • No | • No |
| Central thickness | • Varies with dioptric power | • Varies with dioptric power | • Varies with dioptric power |
| Profile | • Convex-concave | • Convex-concave | • Convex-concave |
Shape & Optics of ICL
- Minus power ICL: Convex anteriorly, concave posteriorly (convex-concave).
- The central thickness decreases with increasing minus power.
- Plus power ICL: Convex anteriorly, concave posteriorly (convex-concave).
- Thicker centrally.
- Toric ICL: Cylindrical power added on the lens surface; alignment marks at the ends of haptics for axis positioning.
- The toricity compensates for corneal astigmatism up to 6.0 D.
Free preview ends here
Keep reading Implantable Collamer Lens (ICL)
20 more sections are included with the Clinical plan.
- Mechanism of Action & Optical Principles
- Anatomical Basis: Ciliary Sulcus & Related Spaces
- Patient Selection & Candidacy Criteria
- Pre-Operative Evaluation & Workup
- ICL Power Calculation
- Vault: Definition, Measurement & Significance