PanOph
Free previewYou're reading the free part of this topic. The rest is included with Clinical.See what's included

Tonometry and IOP Measurement

Glaucoma

Teaching images

9

1. Clinical Analogy

  • Think of the eye as an inflated football.
  • Pressure inside depends on how much air is pumped in versus how much leaks out.
  • Pressing a finger on the football - a firmer ball resists deformation more.
  • Applanation tonometry measures the force needed to flatten a standard area of the cornea and from that infers the intraocular pressure (IOP).
  • The critical challenge: 'wall thickness' (corneal thickness, rigidity) affects the reading.
  • Corneal thickness and biomechanical properties affect applanation tonometry readings.

2. Aqueous Dynamics & IOP Physiology

Teaching image

1

Simplified Goldmann Equation

VariableMeaningNormal Value
PoIntraocular pressure10–21 millimetres of mercury (mmHg) (mean 15.5)
FAqueous flow rate~2–2.5 microlitres per minute (µL/min)
COutflow facility (trabecular outflow)0.28 microlitres per minute per millimetre of mercury (µL/min/mmHg)
PvEpiscleral venous pressure8–10 millimetres of mercury (mmHg)
Notes
  • Po = (F / C) + Pv
  • Diurnal variation:
  • Up to 5 millimetres of mercury (mmHg) in normals.
  • Peak timing varies; healthy individuals may have a nocturnal or early-morning peak.
  • The mechanism is multifactorial and should not be attributed solely to cortisol-related aqueous production.
  • Intraocular pressure is not universally lowest at night; trough timing varies, and healthy individuals may have nocturnal peaks.
  • Variation greater than 8 millimetres of mercury (mmHg) is not established as a universal threshold for clinical suspicion of glaucoma; interpretation depends on the monitoring protocol and clinical context.

Free preview ends here

Keep reading Tonometry and IOP Measurement

11 more sections are included with the Clinical plan.

  • Classification of Tonometers
  • Goldmann Applanation Tonometry (GAT) - Gold Standard
  • Central Corneal Thickness (CCT) & IOP Correction
  • Individual Tonometers - Principles & Pearls
  • Corneal Hysteresis (CH) - Clinical Relevance
  • Diurnal IOP & 24-Hour Monitoring

Clinical plan

Every Learn topic in full, with oral-exam questions and MCQs.

View plans