Free previewYou're reading the free part of this topic. The rest is included with Clinical.See what's included
Tonometry and IOP Measurement
Glaucoma
Teaching images
91. Clinical Analogy
- Think of the eye as an inflated football.
- Pressure inside depends on how much air is pumped in versus how much leaks out.
- Pressing a finger on the football - a firmer ball resists deformation more.
- Applanation tonometry measures the force needed to flatten a standard area of the cornea and from that infers the intraocular pressure (IOP).
- The critical challenge: 'wall thickness' (corneal thickness, rigidity) affects the reading.
- Corneal thickness and biomechanical properties affect applanation tonometry readings.
2. Aqueous Dynamics & IOP Physiology
Teaching image
1Simplified Goldmann Equation
| Variable | Meaning | Normal Value |
|---|---|---|
| Po | Intraocular pressure | 10–21 millimetres of mercury (mmHg) (mean 15.5) |
| F | Aqueous flow rate | ~2–2.5 microlitres per minute (µL/min) |
| C | Outflow facility (trabecular outflow) | 0.28 microlitres per minute per millimetre of mercury (µL/min/mmHg) |
| Pv | Episcleral venous pressure | 8–10 millimetres of mercury (mmHg) |
| Variable | Meaning | Normal Value |
|---|---|---|
| Po | Intraocular pressure | 10–21 millimetres of mercury (mmHg) (mean 15.5) |
| F | Aqueous flow rate | ~2–2.5 microlitres per minute (µL/min) |
| C | Outflow facility (trabecular outflow) | 0.28 microlitres per minute per millimetre of mercury (µL/min/mmHg) |
| Pv | Episcleral venous pressure | 8–10 millimetres of mercury (mmHg) |
Notes
- Po = (F / C) + Pv
- Diurnal variation:
- Up to 5 millimetres of mercury (mmHg) in normals.
- Peak timing varies; healthy individuals may have a nocturnal or early-morning peak.
- The mechanism is multifactorial and should not be attributed solely to cortisol-related aqueous production.
- Intraocular pressure is not universally lowest at night; trough timing varies, and healthy individuals may have nocturnal peaks.
- Variation greater than 8 millimetres of mercury (mmHg) is not established as a universal threshold for clinical suspicion of glaucoma; interpretation depends on the monitoring protocol and clinical context.
Free preview ends here
Keep reading Tonometry and IOP Measurement
11 more sections are included with the Clinical plan.
- Classification of Tonometers
- Goldmann Applanation Tonometry (GAT) - Gold Standard
- Central Corneal Thickness (CCT) & IOP Correction
- Individual Tonometers - Principles & Pearls
- Corneal Hysteresis (CH) - Clinical Relevance
- Diurnal IOP & 24-Hour Monitoring