PanOph
Free previewYou're reading the free part of this topic. The rest is included with Clinical.See what's included

Evisceration, Enucleation and Exenteration

Oculoplasty

Teaching images

9

1. Introduction & Clinical Analogy

Teaching image

1
  • Consider the eye as a watch in its case.
  • Evisceration removes only the watch's internal mechanism (intraocular contents) while keeping the case (sclera, Tenon's, extraocular muscles) intact.
  • Enucleation removes the entire watch and its case but leaves the display cabinet (orbit) untouched.
  • Exenteration demolishes the entire cabinet - orbit, lids, and all soft tissue - when malignancy mandates it.
  • These three procedures define the spectrum of ocular and orbital extirpative surgery.
  • Mastering their indications, nuances, implant selection, and prosthetic rehabilitation is fundamental to any oculoplastics curriculum and is heavily tested in DNB, MRCOphth, and FRCS examinations.

2. Surgical Anatomy of the Anophthalmic Socket

Teaching image

1

Orbital Layers (Outside-In)

LayerSurgical Significance
Skin & orbicularis• Orbicularis oculi supplied by facial nerve (VII) • Orbital septum separates preseptal from orbital tissue
Orbital septum• Fibrous sheet from arcus marginalis • Barrier against fat prolapse
Preaponeurotic fat• Between septum and levator aponeurosis • Preaponeurotic compartment
Tenon's capsule (fascia bulbi)• Dense fibro-elastic coat surrounding globe from limbus to optic nerve • Critical for implant burial
Extraocular muscles• 4 recti + 2 obliques • Insert on sclera and are enveloped by Tenon's capsule • Preserved in evisceration/enucleation for motility
Episclera & sclera• Sclera: principal component of the outer fibrous coat • Episclera: vascular connective-tissue layer external to sclera and continuous with Tenon's capsule • Scleral shell retained in evisceration
Intraocular contents• Uvea, retina, vitreous, lens • Removed in evisceration
Optic nerve• 2.5 centimetres (cm) intraorbital • Contains approximately 1 million axons; reported mean estimates range from 0.5 to 1.2 million • Cut in enucleation at approximately 10 millimetres (mm) behind globe

Vascular Supply

  • Ophthalmic artery → central retinal artery, posterior ciliary arteries (2 long, commonly 6–12 short), muscular branches
  • Long posterior ciliary arteries (LPCAs): run at 3 and 9 o'clock positions - important bleeding points during evisceration
  • Vorticose veins: usually 4, but the number may vary; they exit the posterior sclera in the equatorial region and must be identified and controlled during enucleation

Conjunctival Fornices & Socket Depth

  • The superior fornix (deepest, approximately 15–16 millimeters) and inferior fornix are critical for prosthesis retention.
  • Loss of fornix depth (socket contraction) is an important late complication after extirpative procedures and can impair prosthesis retention.
  • The conjunctival surface transitions to skin at the mucocutaneous junction of the lid margin.

Anatomy Pearl

  • Tenon's capsule has anterior and posterior components: an anterior thick fibrous tissue and a posterior thin fibrous capsule of orbital fat.
  • Orbital implant placement depends on the procedure; in evisceration, described planes include the scleral shell, intraconal space, or posterior to the posterior sclera.
  • The medial and lateral check ligaments are fascial extensions associated with the medial and lateral rectus muscles that attach to the corresponding orbital walls. They help constrain extraocular muscle excursion.
  • Whitnall's ligament (superior transverse ligament) must be preserved during superior fornix dissection to avoid ptosis.

Free preview ends here

Keep reading Evisceration, Enucleation and Exenteration

11 more sections are included with the Clinical plan.

  • The Three E's - Comparison Overview
  • Evisceration
  • Enucleation
  • Exenteration
  • Orbital Implants - Classification & Materials
  • Ocular Prosthetics - Types, Fitting & Care

Clinical plan

Every Learn topic in full, with oral-exam questions and MCQs.

View plans